Smart UPS


High frequency online 10KVA and 6 KVA

 

Detailed Product Description

UPS power supply 10kva
1.pure sine wave
2.Protection against all power problems
3.output: 220/230vac
4. LCD/LED Main Features:

a. Parallel Units with a Single Output of up to 40kVA
b.True N+1 Redundancy
c. DSP Double-Conversion On-line Sinewave Design
d. Input Power Factor Correction
e. Hot-Swappable User Replaceable Batteries
f. LCD Display with Advanced Monitoring for Easy UPS Management
g. Programmable 50/60Hz Frequency Conversion
h. Optional Remote Emergency Power Off (REPO)
i. Wide Input Voltage Window
j. Precision Output Voltage Regulation
k. Superior Brownout, Surge & Transient Protection
l. Optional Extended Battery Banks & Chargers
m. RS-232,Optional SNMP/HTTP Agent
n. WINPOWER® UPS Monitoring & Management Software

Model EH5000-H6K EH5000-H6KS EH5000-H10K EH5000-H10KS
CAPACITY 6000 VA / 4800 W 10000 VA / 8000 W
INPUT
Voltage Range Low Line Transfer 176 VAC @ 100% load / 110 VAC @ 50% load
Low Line Comeback 186 VAC @ 100% load / 120 VAC @ 50% load
High Line Transfer 300 VAC
High Line 290 VAC
Comeback
Frequency Range 46~54 Hz or 56~64 Hz
Phase Single phase with ground
Power Factor ≥0.99 @ 100% load
OUTPUT
AC Voltage Regulation (Bat. Mode) ±1 %
Frequency Range 46~54 Hz or 56~64 Hz
(Synchronized Range)
Frequency Range(Bat. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion <= 3 % THD (Linear Load)/<= 6 % THD(Non-linear Load)
Transfer Time AC to DC Zero
Inverter to Bypass Zero
Waveform (Bat. Mode) Pure Sine Wave
EFFICIENCY
To AC Mode 89%
To Battery Mode 88%
BATTERY
Battery Type 12 V / 7 AH Depending on applications 12 V / 9 AH Depending on applications
Numbers 16 16 16 16
Typical Recharge Time 7 hours recover to 90% capacity Depending on battery capacity 9 hours recover to 90% capacity Depending on battery capacity
Charging Current (max.) 1.0 A 4.0 A 1.0 A 4.0 A
Charging Voltage 273 VDC 273 VDC 273 VDC 273 VDC
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
LED Display Sixteen LEDs indicating UPS status, Load level, Battery level, overload, fault, and programmable outlet
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
OPERATING ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter
CMANAGEMENT
Smart RS-232/USB Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC
Optional SNMP Power management from SNMP manager and web browser